Simulasi Rancang Bangun Jaringan Feeder Untuk Fiber to The Home (FTTH) Pada PT. Indosat

Authors

  • Yus Natali
  • Reka Marinda Dewi

Abstract

ABSTRAK
Simulasi rancang bangun jaringan feeder untuk Fiber To The Home (FTTH) yaitu dengan penentuan
perangkat berupa spesifikasi perangkat dan tataletak jaringan feeder untuk Fiber To The Home (FTTH) dan
disimulasikan menggunakan Optisystem.Topologi jaringan feeder yang digunakan dalam perancangan jaringan
Fiber To The Home (FTTH) menggunakan topologi jaringan Point To Point dimana pusat titik jaringan yaitu CO
(Central Office) sebagai OLT (Optical Line Terminal) dan ODC (Optical Distribution Cabinet) sebagai pusat
terminasi dan distribusi jaringan. Dari simulasi pada ODC A nilai (Pr) = -9.606 dBm, nilai α tot = 11.606 dB,
Untuk perhitungan (Pr) = -11.0863 dBm, dan nilai α tot = 13.0863. Pada ODC B nilai (Pr) = -9.617 dBm, nilai α
tot = 11.617 dB, Untuk perhitungan (Pr) = -11.0751 dBm, dan nilai α tot = 13.0751. Pada ODC nilai (Pr) = -10.513
dBm, nilai α tot = 12.513 dB, Untuk perhitungan nilai (Pr) = -11.9831 dBm, dan nilai α tot = 13.9831. Hal ini
menunjukkan link memenuhi kelayakan PT. Indosat yaitu α tot maksimum 28 dB dan maksimum ITU-T G984.2
yaitu 28 dB dengan Prx yang masih berada pada batas sensitivitas penerima yaitu [2;-28] dBm.
Kata kunci: FTTH, Feeder, Power Link Budget, OPM, Optisystem
ABSTRACT
The simulation of the network feeder design for Fiber To The Home (FTTH) is by determining the
device in the form of device specification and network feeder layout for Fiber To The Home (FTTH) and
simulated using Optisystem. The network feeder topology used in the design of Fiber To The Home (FTTH)
network uses the Point To Point network topology where the central point of the network is CO (Central Office)
as OLT (Optical Line Terminal) and ODC (Optical Distribution Cabinet) as the termination and distribution
center network. From the simulation on ODC A the value (Pr) = -9.606 dBm, the value of α tot = 11606 dB, For
calculation (Pr) = -11.0863 dBm, and the value of α tot = 13.0863. In ODC B the value (Pr) = -9.617 dBm, the
value of α tot = 11,617 dB, For calculation (Pr) = -11.0751 dBm, and the value of α tot = 13.0751. At ODC the
value (Pr) = -10.513 dBm, the value of α tot = 12.513 dB, For the calculation of the value (Pr) = -11.9831 dBm,
and the value of α tot = 13.9831. This shows the link to meet the feasibility of PT. Indosat ie maximum α tot 28
dB and maximum ITU-T G984.2 is 28 dB with Prx which is still at the sensitivity limit of receiver that is [2; -28]
dBm.
Keywords: FTTH, Feeder, Power Link Budget, OPM, Optisystem